Acidity test of transformer oil pdf

A larger quantity of oil is needed for these tests. The pfvo and sfl are run concurrently from the same test setup. The main physical and chemical properties tested in transformer oil testing methods are the oils dielectric strength, dissipation factor, flashpoint, color, amount of solid particulate matter, water content, gas content and the oils acid number. Use our free transformer asset management tool to automatically assess your transformers health. Minimum standard specific resistance of transformer oil at 90c is 35. Excessive oxidation accelerates the slug formation rates in the oil. Transformer oil maintenance electric energy online. Transformer oil acidity test kit procedure, precautions and. Aug 30, 2019 transformer oil also known as insulating oil is a special type of oil which has excellent electrical insulating properties and is stable at high temperatures. No general correlation is known between acid number and the corrosive tendency of oils toward metals. The transformer oil is used in the transformer for insulation as well as for cooling purpose. If the soil bubbles or fizzes, the soil is highly acidic. Samples are usually sent to a laboratory for transformer oil analysis.

Transformer oil acidity test kit determination of acidity of transformer oil this kit is developed following the tests recommended by the central power research institute, bangalore introduction the acid content of transformer oil is determined during service to prevent any damage due to. As oils age in service the acidity, and therefore the acid number, increases. A car requires oil for lubrication while a transformer requires oil for insulation and cooling. Transformer oil acidity test kit procedure, precautions and color chart 1. These organic acids are detrimental to the insulation system and can induce corrosion inside the transformer when water is present. The ieee has suggested guidelines for ift values depending on the type of oil and the unit it is being used in ieee c57.

Astm d974 the acidity number reflects the amount of potassium hydroxide k oh needed to neutralize 1 gram of oil. Dielectric strength, breakdown voltage and acidity test. These include the chemical and causes of the specific physical properties of the test oils. Acidity contnet test is done on transformer oil to measure the acidity content of oil its unit is mgkohgm of oil.

Test methods by the american society for testing of. It consists of one polythene bottle of rectified spirit ethyl alcohol, one polythene bottle of sodium carbonate solution and one bottle of universal indicator liquid. The acid number of an oil is a measure of the amount of acidic materials present. For mineral oil, a generally accepted maximum moisture content is 35 ppm. Transformer oil is used in oil filled electrical power transformers to insulate, stop arcing and corona discharge, and to dissipate the heat of the transformer i. Dissolved gas analysis dga is the study of dissolved gases in transformer oil. A rating of 30 kv is the minimum breakdown voltage at which transformer oil can be safely used in a power transformer. The effect of acid accumulation in powertransformer oil on. Its use to call transformer oil and it a little bit pricey. Dielectric strength, specific resistance, dielectric dissipation factor. Transformer oil acidity test, transformer oil acidity test. Iec 60296 is a recognized, continually updated, international standard and applicable to specifications and test methods for unused mineral insulating oils.

In this post, i will explain everything about this experiment and i will also provide you a live video link that you. Caltran 6040 group i is a superior paraffinic transformer oil that fully meets iec 60296, ed. Acids can also come from external sources such as atmospheric contamination. Puma transformer oil unit test method specification limits typical data physical property min max appearance iec 60296 clear, free from sediment complies density, 20. Testing equipments oil purification systems,transformer oil. Breakdown voltage is measured by observing at what voltage, sparking straits between two electrodes emerged in the oil, separated by specific gap. Acids and other oxidation products will, in conjun. Transformer oil also known as insulating oil is a special type of oil which has excellent electrical insulating properties and is stable at high temperatures. Acidity test of transformer oil powerlink refinery ltd. The different insulating materials have different dielectric strength.

The acidity of oil in a transformer should never be allowed to exceed 0. If no reaction occurs, scoop a fresh soil sample into a second container. Use our free transformer asset management tool to automatically assess your transformer s health. It may also causes abnormal deterioration of paper used for insulation in the transformer windings. Aselectretech kolkata transformer oil acidity test kit chain. The effect of acid accumulation in powertransformer oil. Dissolved gas analysis of transformer oil electrical4u. Acore can supply oil testing equipment including transformer oil breakdown voltage tester, oil viscosity tester, acidity tester,flash point tester,dga dissolved gas tester,etc. Bdvbreakdown voltage value above 30kv is considered good. Hzcs3 transformer oil acidity test kit made in china. If oil becomes acidic, water content in the oil becomes more soluble to. The acidity of a used oil is due to the formation of acidic oxidation products.

Sep 17, 20 transformer oil acidity test kit procedure, precautions and color chart 1. In this post, i will explain everything about this experiment and i will also. The megger guide to insulating oil dielectric breakdown. This paper presented the qualitative assessment of transformer insulating oil. Furan testing of transformers oil linkedin slideshare.

The effect of acid accumulation in powertransformer oil on the aging rate of paper insulation article pdf available in ieee electrical insulation magazine 303. In general, acidic byproducts produce increased dielectric loss, increased corrosivity, and may cause. If lower values are recorded do not energize the transformer and the oil is recommended for filtration. This test helps to determine the acid number or acidity of the oil which can be caused by the oxidation process of the insulation forming acids and sludge formation. The acidity test measures the content of acids formed by oxidation and contaminates. Materials astm provides that the acidity of oil in a. In chapter three and four, an extended discussion on the transformer oil properties is made, taking into consideration the eleven most important ones. Transformer oil hp transformer oil i hp lubricants. The acidity alone may not cause a transformer failure, but it can indicate aging of the oil and sludge buildup. The screen test is a collection of physical, electrical and chemical tests for the transformer oil. About 90% of these are testing equipment, 1% are blood pressure monitor. Puma transformer oil transformer fluid uninhibited puma transformer oil is product specially developed for use in oilfilled electrical equipment including power and distribution transformers, rectifiers, circuit breakers and switchgears. Assessing remnant life of transformer based on furan.

For portable acidity testing kit for transformer oil procedure. The acidity level of transformer oil is measured as per british standard bs2000 part 1. The instrument in improving the efficiency and test accuracy meanwhile,reduce operator contact sample and reagent,the maximum guarantee its safety. The megger guide to insulating oil dielectric breakdown testing. Pdf significance of transformer oil testing researchgate. This test does not measure the water content in the transformer paper insulation. The sfl is the number of hours the oil remains sludgefree. These tests include dielectric breakdown, power factor, interfacial tension, acidity, and color. Mineral oil is the most common insulating fluid and. You can download a free pdf of these and other limits here.

March 2017, page 2 doble engineering company, 85 walnut street, watertown, ma 02472 usa. Increased acidity of the oil, causes decrease in resistivity of the oil. Dielectric strength, breakdown voltage and acidity test with. This test will be performed when your power transformer cooling system is an oil type. Transformer oil acidity test kit determination of acidity of transformer oil this kit is developed following the tests recommended by the central power research institute, bangalore introduction the acid content of transformer oil is determined during. Perhaps, the easiest way to explain the reasoning for proper transformer oil maintenance is to compare a transformer to a car. For power system, industrial and mining enterprises, there have a lot of oil filled electrical equipment, so the acid value of the transformer oil and turbine oil is.

The reaction youre seeing is the result of acidic soil coming into contact with an alkaline substance baking soda. Only about three percent of the crude oil is appropriate for production of transformer oil. In addition to the dga test, additional oil samples can be taken to detect moisture, interfacial tension, acidity, furans, dissolved metals, and metal particle count indicates pump problems. Compounded engine oils can and usually do have both acid. Inhibited transformer oils can extend the service life of transformer oil. Transformer oil testing is one of the important parts of a power transformer. Acidity test of transformer insulating oil electrical4u. What is the bdv value of distribution transformer oil. Skraceni maintenance and repair of medium power transformers. Today, all of meggers oil test set design, development and manufacture is carried out at the companys.

Monarch controls m414, 1 st stage, 8 th cross peenya industrial estate bangalore 560058 ph. Again, measuring the acidity reveals only symptoms of a problem. Just as a car requires regular checks of both oil quality and oil level, a transformer requires the same proactive treatment. It is an optional component in high vacuum transformer oil filtration machine which is provided if the customer demands it. Although the titration is made under definite equilibrium conditions, the method does not measure an absolute acidic or basic property that can be used to predict performance of an oil under service conditions. A used oil having a high acid number indicates the oil is either oxidized or contaminated with materials such as varnish, paint or other foreign matter. Mineral oil is the most common insulating fluid and has been in use since the late 19th century. As acid values increase, usually due to oxidation of the oil, the insulating quality of the oil decreases. The bdv test measures the dielectric strength of the oil using an oil tester. Acidity the acidity test is used to estimate the total acid value of the transformer insulating liquid. Transformer oil acidity test kit procedure, precautions. If regularly conducted, oil analysis allows identification of specific fault conditions that may be developing. Meggers experience in the design and production of oil test sets also reaches back to the early 20th century, when pioneering equipment was produced by foster transformers, a company that became part of megger group in 1968.

Assessing remnant life of transformer based on furan content. Types of transformer field tests and diagnostics bright. Maintenance and repair of medium power transformers. This is the critical acid number and deterioration increases rapidly once this level is exceed. Acore can supply oil testing equipment including transformer oil breakdown voltage tester,oil viscosity tester,acidity tester,flash point tester,dga dissolved gas tester,etc. Astm d974 acids in the oil originate from oil decompositionoxidation products. Transformer oil testing is a proven loss prevention technique that should be a part of any condition based predictive. Such an event will not affect the acidity but would markedly affect the ift and dielectric strength of the oil. The acidity test of transformer oil can be experimented by titration method. An increase in the acidity is an indication of the rate of deterioration of the oil with sludge as the inevitable byproduct of an acid situation which is neglected.

Automatic potentiometric titration iso 2719, determination of flash point penskymartens closed cup method. Oil quality measuring moisture, acidity, solid contamination and breakdown. This test helps to indicate the dielectric loss leakage current of the oil. Acidity measures the acid levels in the transformer liquid. To gather the sample, a clean, moisture free container must be used typically a plastic. Breakdown voltage value of insulating oil of the transformer. Same nine samples were investigated for acidity value by means of. Astm d974 14e2 standard test method for acid and base. Good oxidation stability is necessary in order to maximize the service life of the oil by minimizing the formation of sludge and acid. The transformer oil was drained, bell tank lifted and paper samples were taken from 25 different locations for the dp test. Hp transformer oil i is inhibited type transformer oil meeting is.

From the test results it shall be identified that acidity content is high for degraded oil. Aug 08, 2017 transformer oil testing is one of the important parts of a power transformer. A wide variety of transformer oil acidity test options are available to you, such as electronic, hydraulic. Hzcs 1 automatic oil acidity test kit single cup extraction method feature 1,improve work efficiency and precision while reducing operator contact with the sample and reagents, to maximize the protection of their personal safety. The paper samples from top 23 layers of the winding leads and the pressboard samples were taken for the measurement of dp from various locations. Insulating medium mineral oil unit transformer volume litres 900 laboratory ref. This test helps to understand the paper degradation rate. Because of the importance of the power transformers in electrical networks, permanently taking care of the oil quality is vital. Transformer oil tests dielectric breakdown voltage min value 1mm gap 2mm gap 23 40 28 47 30 50 neutralisation number acidity mg kohg max value 0. When the fault is major, the production of decomposed gases are significant and they get collected in a. Astm d117 18 standard guide for sampling, test methods. The breakdown voltage, dielectric and acidity tests were electrically and chemically carried out on sixteen samples of transformer insulating oil collected from various serving distribution transformers in ilorin metropolis in nigeria, through the supply authority.

Aselectretech kolkata transformer oil acidity test kit. Testing equipment transformer oil breakdown voltage. As acid levels increase, the quality of the oil decreases, causing dielectric loss, corrosion, and thermal problems from sludge. Acids in the oil originate from oil decompositionoxidation products.

We can determine the acidity of transformer insulating oil, by a simple portable acidity test kit. Power transformer oil testing an electrical engineer. Specific gravity verifies the weight to provide the type of insulating fluid. Designed to perform puma transformer oil fulfils the requirements for nrs 0791. Hzcs3 transformer oil acidity test kit made in china hzcs. So both resistivity test and tan delta test of transformer oil are generally not required transfformer the same piece of the insulator or insulating oil. Standard test method for oxidation stability of mineral. Whenever a transformer undergoes abnormal thermal and electrical stresses, certain gases are produced due to the decomposition of the transformer oil. Hzcs3 transformer oil acidity test kit product overview. Transformer oil analysis basic introduction by n robinson, wearcheck as blood tests disclose ones state of health, so oil analyses disclose the condition of a transformer. Acidity contnet test is done on transformer oil to measure the acidity content of oil its unit is.